ukuran spandrel single aluminium 10 cm Profile Span Limits and Installed Cost per m2
When facade contractors in Southeast Asia ask about ukuran spandrel single aluminium, they are rarely asking for a single number. What they actually need is clarity on how the 10 cm single spandrel profile compares to wider variants in terms of coverage rate, structural spanning capacity, and installed cost per square meter. This article isolates the 100 mm single spandrel profile — the most commonly specified width in Indonesian and Malaysian commercial ceiling and wall cladding projects — and examines its dimensional logic, load-bearing behaviour across different support spacings, and the hidden cost drivers that separate a budget installation from one that stays flat and silent for 15 years. Every figure here is drawn from field measurement protocols used by quantity surveyors and facade engineers on active tenders.
What the 10 cm Single Spandrel Profile Actually Measures
The term ukuran spandrel single aluminium is often thrown around loosely on supplier websites and marketplace listings, but the dimensional reality of the 10 cm single spandrel is more precise than most catalogues suggest. A standard single spandrel profile marketed as "10 cm" carries a face width of approximately 100 mm after interlocking, with a profile depth ranging between 16 mm and 20 mm depending on the extrusion die. The aluminium alloy is almost universally 6063-T5, selected for its extrudability and adequate post-painting strength. Wall thickness on legitimate architectural-grade stock sits at 0.40 mm to 0.55 mm, though the Indonesian market is flooded with 0.30 mm and even 0.25 mm variants sold through consumer platforms.
Why does a half-millimetre matter? Because the profile relies entirely on its longitudinal bending stiffness. The section modulus of a 100 mm wide, 18 mm deep channel with 0.45 mm walls is modest. When installed as a ceiling with supports at 1200 mm centres, the mid-span deflection under self-weight alone can exceed 3 mm if the alloy temper has been degraded by poor extrusion cooling. This is the first dimension that engineers should verify on incoming batches: not the face width, which is visible, but the web thickness at the interlock groove, where thinning during extrusion is most aggressive.
A reliable reference for 6063-T5 mechanical properties is the Aluminium Association's Teal Sheets, which provide the minimum tensile strength of 150 MPa and yield strength of 110 MPa. Contractors should request mill certificates that reference these values rather than accepting a supplier's verbal assurance that "it's standard 6063."
Why Profile Depth Dictates Span Limits More Than Width
The single spandrel profile's spanning capacity is governed less by its 100 mm face width than by its profile depth — a point frequently misunderstood during value engineering. For a uniformly loaded simply supported beam, deflection varies with the cube of depth. This means an 18 mm deep spandrel deflects roughly 42% more than a 20 mm deep profile under identical load and span. When a contractor substitutes a cheaper 16 mm deep extrusion to save on aluminium tonnage, the allowable support spacing drops disproportionately.
Consider a typical interior ceiling application with 0.45 mm wall thickness, 100 mm face width, and 18 mm profile depth. At a support spacing of 1000 mm, self-weight deflection remains below 1.5 mm — acceptable for most visual criteria. Push that spacing to 1500 mm, and deflection jumps to approximately 5 mm, which is visible from floor level under oblique lighting. For exterior soffit applications where wind suction adds to self-weight, the same profile may need supports at 600 mm to 800 mm centres depending on the local wind zone.
The table below provides deflection estimates for three common single spandrel configurations under self-weight only. These are calculated values based on 6063-T5 modulus and should be adjusted for coating mass and any superimposed insulation load.
| Profile Depth (mm) | Wall Thickness (mm) | Support Spacing (mm) | Mid-Span Deflection (mm) | Recommended Application |
|---|---|---|---|---|
| 16 | 0.40 | 1000 | 2.8 | Interior ceiling, low visibility |
| 18 | 0.45 | 1000 | 1.5 | Interior ceiling, standard commercial |
| 18 | 0.45 | 1200 | 3.1 | Interior ceiling, borderline |
| 20 | 0.50 | 1200 | 1.8 | Exterior soffit, sheltered |
| 20 | 0.50 | 1500 | 4.2 | Not recommended without mid-span clip |
These numbers assume the profile is simply supported at both ends with no rotational restraint. In practice, the interlocking geometry between adjacent planks provides partial lateral coupling that can reduce differential deflection between neighbouring panels — but never rely on this to justify overspanned layouts.
Coating Thickness and the 10 cm Profile: Why It Matters for Exterior Use
When ukuran spandrel single aluminium is specified for exterior wall cladding or exposed soffits, the conversation must shift from dimensional tolerances to coating durability. The 10 cm single spandrel is frequently powder-coated with a polyester or super-durable polyester formulation. However, exterior applications in tropical climates with high UV exposure demand a minimum powder coat thickness of 60 microns, tested to Qualicoat Class 2 or equivalent. Anything below 50 microns on an exterior spandrel will show chalk within 3 to 5 years in equatorial sun.
A practical verification method: cut a 20 mm sample from a production-length plank, mount it in cross-section, and measure coating build under a microscope at the groove root and at the face centre. The groove root is where coating thickness drops during electrostatic application due to the Faraday cage effect. If the groove root measures below 40 microns on a batch claimed to be 60 microns nominal, reject the batch. This is not a cosmetic issue — it is where filiform corrosion initiates on 6063 alloy in humid coastal air.
For projects within 5 km of saltwater, consider specifying a chromate pre-treatment under the powder coat rather than the standard chrome-free conversion coating. The incremental cost is approximately IDR 8,000 to 12,000 per square meter of installed spandrel area, which is negligible against the cost of replacing corroded panels after 7 years.
Coverage Rate Calculation: How Many Linear Meters Make a Square Meter
One of the most frequent estimation errors on spandrel single aluminium projects is miscalculating the linear-meter-to-square-meter conversion. A 100 mm face width profile, once interlocked, has an effective coverage width of approximately 98 mm to 100 mm depending on the specific interlock geometry. At exactly 100 mm coverage, 10 linear meters yield 1.0 m² of installed ceiling or wall area. This seems straightforward until the estimator forgets that the first and last planks in a row require edge trimming, which reduces net coverage by half a plank width at each boundary.
For a ceiling bay measuring 4800 mm by 3600 mm with planks running parallel to the short dimension, the calculation runs as follows: 4800 mm ÷ 100 mm = 48 planks. Each plank is 3600 mm long. Total linear meters = 48 × 3.6 m = 172.8 m. Gross area = 17.28 m². Add 3% for cutting waste at both ends and for offcuts that are too short to reuse: 178.0 linear meters ordered. At a typical supply price of IDR 28,000 to IDR 45,000 per linear meter for 0.45 mm, 18 mm deep, powder-coated single spandrel, the material cost for this bay ranges from IDR 4.98 million to IDR 8.01 million before support rails and clips.
Suppliers like Futeng® provide batch-specific coverage data with each shipment, listing the exact effective width measured from a 10-plank assembly rather than from a single profile. This accounts for the cumulative tolerance stack across interlocking joints, which can shrink the effective coverage by 1 mm to 2 mm per plank on lower-grade extrusions.
Support Rail Spacing and the Hidden Cost of Overdesign
The support rail — typically a galvanized steel hat channel or an aluminium T-bar — is the single largest cost driver after the spandrel planks themselves. Specifying rails at 600 mm centres when 1000 mm would suffice adds roughly 40% to the substructure cost. For a 10,000 m² commercial ceiling, that difference can exceed IDR 350 million in steel and labour.
How do you determine the maximum allowable rail spacing for a given ukuran spandrel single aluminium? The limiting criterion is almost never ultimate strength. A 6063-T5 spandrel at 1200 mm span will not collapse under self-weight. The governing limit is visual deflection under the combined weight of the plank plus any insulation blanket or service load resting on the ceiling grid. Industry practice in Indonesia and Malaysia commonly accepts L/360 as the deflection limit for visible ceilings, where L is the span between supports. For a 1200 mm span, L/360 = 3.3 mm. If the calculated deflection exceeds this, either reduce the rail spacing or increase the profile depth.
A practical field check: before signing off on rail spacing, request the extrusion supplier's section properties drawing. Look for Ixx (moment of inertia about the horizontal axis). For a 100 mm wide, 18 mm deep channel with 0.45 mm wall, Ixx is typically in the range of 1.2 to 1.8 cm⁴. Run a quick deflection check using δ = (5 × w × L⁴) / (384 × E × I), where w is the distributed load per unit length, E = 69,000 MPa for 6063-T5, and I is in m⁴. If the supplier cannot provide Ixx, find another supplier.
Thermal Movement in Long Runs: The 6-Meter Rule
Aluminium expands at approximately 23 × 10⁻⁶ per °C. A 6-meter length of spandrel single aluminium subjected to a 40°C temperature swing (night to midday under a metal roof) grows by 5.5 mm. If both ends are rigidly fixed, that expansion translates into compressive stress that can buckle the plank out of its interlocking plane. This is particularly problematic on exterior soffits where dark-coloured planks absorb solar radiation and reach surface temperatures 20°C to 30°C above ambient air.
The industry rule of thumb is to provide an expansion joint every 6 linear meters along the plank direction, with a minimum 10 mm gap. For interior air-conditioned ceilings where the temperature swing is smaller, 8-meter runs are generally acceptable. When calculating material quantities, remember that each expansion joint consumes roughly 50 mm to 80 mm of plank length that does not contribute to net coverage. On a 100-meter-long facade with joints every 6 meters, you lose approximately 1.7 meters of coverage to expansion gaps — factor this into the linear meter order quantity.
Aluminium Association guidelines on thermal movement provide detailed design recommendations for extruded aluminium building products and are worth consulting for projects in extreme climates.
Interlock Geometry: Why Not All Single Spandrels Are Interchangeable
A recurring headache on projects that split orders across multiple suppliers is interlock incompatibility. The 10 cm single spandrel profile from Supplier A may have a 3.5 mm deep female groove with a 1.2 mm throat opening, while Supplier B's version uses a 4.0 mm groove with a 1.5 mm throat. The two will not mate cleanly. Worse, they may appear to engage during installation but separate under thermal cycling or vibration from overhead MEP equipment.
When a project specification calls for ukuran spandrel single aluminium without locking the supplier, the contractor must either source the entire quantity from one extrusion house or physically test interlock compatibility between proposed sources before awarding the order. The test is simple: assemble a 5-plank row using alternating planks from each supplier, lift one end, and check for relative vertical displacement between adjacent planks. Any movement exceeding 0.5 mm at the interlock joint under a 2 kg point load applied mid-span is grounds for rejection.
A related issue is the clip profile. The support clip that snaps into the female groove of the spandrel must match the groove geometry precisely. A loose clip allows the plank to rattle; an oversized clip deforms the groove and permanently damages the profile during installation. Always source clips from the same supplier as the spandrel extrusion, and insist on a clip retention test report showing pull-out force for the specific profile-clip combination.
Cost Breakdown for a Typical 1000 m² Interior Ceiling
To ground the discussion in real tender numbers, here is a unit rate build-up for a 1000 m² interior suspended ceiling using 10 cm single spandrel aluminium with 0.45 mm wall, 18 mm depth, polyester powder coat, supported on galvanized steel hat channels at 1000 mm centres. Prices are indicative for Q3 2026 in the Jabodetabek market and should be adjusted for location and volume.
| Cost Item | Unit | Quantity per m² | Unit Rate (IDR) | Amount per m² (IDR) |
|---|---|---|---|---|
| Single spandrel 10 cm, 0.45 mm, powder coated | linear m | 10.3 | 35,000 | 360,500 |
| Galvanized hat channel 40×20×0.8 mm | linear m | 1.05 | 22,000 | 23,100 |
| Support clips (spring steel) | pcs | 10.5 | 2,500 | 26,250 |
| Suspension rods M6, 1000 mm, with anchors | set | 1.05 | 18,000 | 18,900 |
| Installation labour (trained crew) | m² | 1.0 | 85,000 | 85,000 |
| Cutting waste, sundries, and consumables | lump sum | 5% of materials | - | 21,438 |
| Total installed cost per m² | 535,188 |
At this unit rate, a 1000 m² ceiling costs approximately IDR 535 million installed. Reducing the plank wall thickness from 0.45 mm to 0.35 mm saves roughly IDR 42,000 per m² in material, but the resulting increase in deflection demands tighter rail spacing — adding back roughly IDR 35,000 per m² in substructure and clips. The net saving is marginal, and the thinner plank is more susceptible to handling damage during installation. For most commercial projects, the 0.45 mm wall at 18 mm depth represents the optimum balance of material cost and spanning performance.
Factory vs. Site Cutting: Where the Dimensional Risk Sits
Single spandrel planks arrive from the extrusion plant in standard lengths — typically 5.8 meters or 6.0 meters, dictated by container dimensions and anodizing tank sizes. Cutting to project-specific lengths happens either at the supplier's facility or on site with a chop saw. Each approach carries different risks for ukuran spandrel single aluminium accuracy.
Factory cutting offers a tolerance of ±0.5 mm on length and clean, burr-free ends. The cost adder is roughly IDR 5,000 per cut. Site cutting is cheaper in theory — the contractor's own labour, a single chop saw, no transport markup — but the reality is that site-cut ends are rarely square within 1 mm, and the burr left by a dull blade scratches the coating on adjacent planks during interlocking. Over a 5000-plank project, the time spent deburring site-cut ends erases any labour saving.
Recommendation: for projects exceeding 500 m², specify factory-cut lengths with a detailed cutting schedule submitted by the contractor and approved before extrusion. The schedule should account for expansion joints, edge trim, and the 3% cutting waste factor already discussed. Factory-cut planks also allow the supplier to apply edge touch-up coating before packing, something that is almost never done properly on site.
Fire Performance and the Single Spandrel Ceiling
Aluminium itself is non-combustible (Euroclass A1 per EN 13501-1), but the powder coating on a single spandrel plank is organic and will contribute to fire load. For ceiling applications in buildings requiring a fire-rated assembly, the relevant test is not the plank material alone but the complete ceiling system — planks, support grid, and any cavity insulation.
A typical 10 cm single spandrel ceiling with 0.45 mm plank, steel hat channels, and no cavity insulation achieves Class 0 surface spread of flame under BS 476-6/7 and meets the requirements of ASTM E84 Class A with a flame spread index below 25. Adding a polyethylene vapour barrier or acoustic fleece above the planks changes the classification — the assembly must be tested as a whole. Specifiers should request a fire test report for the specific ceiling build-up, not just a material certificate for the aluminium extrusion.
In Indonesian practice, many commercial ceilings are installed without formal fire engineering review because "aluminium doesn't burn." This is a dangerous oversimplification. At 660°C, aluminium loses essentially all structural strength. A ceiling fire from below, fuelled by contents, can reach this temperature within 15 to 20 minutes. The spandrel planks will sag and disengage from their clips long before the structural steel above reaches critical temperature. For buildings requiring 60-minute ceiling integrity, a single spandrel aluminium ceiling alone is insufficient — a separate fire-rated membrane is needed above the ceiling plane.
Procurement Checklist for International Buyers
For procurement managers outside Indonesia sourcing ukuran spandrel single aluminium from Asian mills, the following verification sequence reduces the risk of receiving dimensionally non-compliant material:
- Request a 300 mm physical sample from the production batch before shipment. Measure face width, profile depth, and web thickness at three points along the sample using calibrated callipers.
- Cross-section the sample and measure coating thickness at the face centre and groove root under 50× magnification.
- Assemble a 5-plank test row using samples from different production shifts. Measure the assembled width and verify that the effective coverage per plank matches the supplier's stated value within ±0.5 mm.
- Verify the alloy temper by requesting a hardness test result — 6063-T5 should read 60 HB minimum on the Brinell scale.
- Check the interlock engagement force: a correctly matched plank and clip should require 15 N to 25 N to engage and should not separate under a 50 N pull force applied perpendicular to the ceiling plane.
Suppliers that resist providing this data or claim it is "not standard practice" should be disqualified. The cost of a rejected container far exceeds the cost of a pre-shipment inspection. Futeng® and other established mills maintain in-house testing capability for all the parameters listed above and provide batch-specific reports as standard documentation with each export shipment.
When the 10 cm Profile Is the Wrong Choice
This article has focused on the 10 cm single spandrel because it dominates the market, but there are applications where specifying it is a mistake. For exterior wall cladding on buildings taller than 30 meters, the 10 cm profile's modest section modulus makes it vulnerable to wind-induced vibration unless the support spacing is reduced below 600 mm — at which point the substructure cost erases any material saving relative to a deeper profile.
For curved ceilings, the 10 cm single spandrel can follow a gentle radius if the planks are curved during extrusion or post-formed, but the interlock becomes progressively stiffer as the radius tightens. Below a 3000 mm radius, the planks will not interlock without permanent deformation of the groove. Wider spandrel profiles (150 mm, 200 mm) with deeper webs handle curvature better because the web depth provides leverage for bending without twisting the interlock.
The decision to use ukuran spandrel single aluminium of 10 cm should be based on a rational trade-off: material cost per square meter versus spanning performance versus installation speed. The 10 cm profile wins on material cost and is the fastest to install due to its light weight, but it demands closer support spacing and is less forgiving of installation errors than wider, deeper alternatives. For most interior commercial ceilings up to 5000 m² with support rails at 1000 mm centres, it remains the logical specification. Push beyond those boundaries, and the engineering case weakens.